RFB 505


RFB 505

  • Frequency range: 87.5 ÷ 108 MHz
  • Input power: 12 W nom./20W max.
  • Output power: 500W
  • Output power stability with ALC: ÷ 3%
  • Harmonic attenuation: <70 dBc
  • Input/output impedance: 50 Ohm
  • Input connector: N
  • Output connector: N
  • RF Monitor output connector: BNC
  • Line voltage: 190 ÷  264 VAC
  • Overall consumption: 1200 VA
  • Maximum current admitted on auxiliary outlets: 1 A @ 230 VAC, no fuse
  • Operating temperature: 0 ÷ +35° C nominal, -10 ÷ +45° C max
  • Dimensions: 42 X 18 X 52 (W - H - L)
  • Weight: 27 Kg

RFB 1005


rfb1005

  • Frequency range: 87.5 ÷ 108 MHz
  • Input power:12 W nom. / 20 max.
  • Output power: 1000 W ÷ 0,5 dB
  • Output monitor attenuation: 54 dB, typ.
  • Harmonic attenuation: <70 dBc
  • Input/output impedance: 50 Ohm
  • Input connector: N
  • Output connector: 7 / 16"  
  • RF Monitor output connector: BNC
  • Line voltage 190 ÷ 264 VAC 50/60Hz
  • Overall consumption: 2000 VA
  • Maximum current admitted on auxiliary outlets: 1 A @ 230 VAC, no fuse
  • Operating temperature: 0 ÷ 35° C nominal, -10 ÷ 45° C max
  • Dimensions:42 X 18 X 52 (W - H - L)
  • Weight:30 Kg

RFB 2005


RFB2005

  • Frequency range: 87.5 ÷ 108 MHz
  • Input power:  20  W nom. / 35 W max.
  • Output power: 2000W ÷ 0,5 dB
  • Output monitor attenuation: 54 dB, typ.
  • Harmonic attenuation: <75 dBc
  • Input/output impedance: 50 Ohm
  • Input connector: N
  • Output connector: 7 / 16"  
  • RF Monitor output connector: BNC
  • Single-phase line voltage: 190 ÷ 264 VAC 50/60 Hz
  • Three-phase line voltage (optional)  400 VAC
  • Overall consumption: 5200 VA Single-phase - 4000VA Three-phase
  • Maximum current admitted on auxiliary outlets: 1 A @ 230 VAC, no fuse
  • Operating temperature: 0 ÷ 35° C nominal, -10 ÷ 45° C max
  • Dimensions: 42 X 30 X 58 (W - H - L)
  • Weight:48 Kg

RFB 5005


tx5005

  • Frequency range: 87,5  ÷ 108 MHz
  • Input power, typical/max.:  100   /  130 W
  • Output power: 5000 W  ± 0,5 dB  
  • Output power stability with ALC:      ±3%
  • Harmonic attenuation: <70dB
  • IN/OUT impedance: 50 Ohm
  • IN connector: type N
  • OUT connector:  7/8"
  • RF Monitor output connector:  BNC
  • Three-phase line voltage: 400  VAC (± 15%)
  • Overall consumption: <10 kVA - P.F. >0.99
  • Maximum current admitted on auxiliary outlets: 3 A @ 230 VAC fused
  • Operating temperature:  0 ÷ 35°C  nominal,  -5 ÷ +50 °C max
  • Dimensions: 19" rack  
  • Weight: 260 kg.

RFB 10005


tx1005

  • Frequency range: 87,5 ÷ 108 MHz
  • Input power, tipica/max:250 / 300 W
  • Output power: 10000 W  ± 0,5 dB  
  • Output power stability with ALC: ±3%
  • Harmonic attenuation: >70dB
  • IN/OUT connector: 50 Ohm
  • IN connector: type N
  • OUT connector: 1" 5/8
  • RF Monitor connector: BNC
  • Three-phase line voltage: 400 VAC (± 15%)
  • Overall consumption: <20kVA - P.F. >0,99
  • Maximum current admitted on auxiliary outlets: 6,3 A @ 230 VAC  fused
  • Operating temperature: 0  ÷ 35°C  nominal -5  ÷ 50 °C max
  • Dimensions: 19" standard - 40 unit rack
  • Weight: 610 kg.

RFB 20005


rfb20005

  • Frequency range: 87,5 ÷ 108 MHz
  • Input power, typical/max: 1000 W
  • Output power: 20000 W  ± 0,5 dB  
  • Output power stability with ALC: ±3%
  • Harmonic and spourius emission: -83dBm
  • IN/OUT connector: 50 Ohm
  • IN connector: type 7/16
  • OUT connector: 3" 18
  • RF Monitor connector: BNC
  • Three-phase line voltage:208/230/ 400 VAC (± 15%)
  • Overall consumption: <36kVA - P.F. >0,99
  • Maximum current admitted on auxiliary outlets: 6,3A@230VAC  fused
  • Operating temperature: 0  ÷ 35°C  nominal -5  ÷ 50 °C max
  • Dimensions: 2x19" standard - 80 unit rack
  • Weight: 1500kg.

RFB 30005


RFB30005

  • Frequency range: 87,5 ÷ 108 MHz
  • Input power, typical/max: 800 / 1000 W
  • Output power: 30.000 W  ± 0,5 dB  
  • Output power stability with ALC: ±3%
  • Harmonic and spurius emission: -80dBm
  • IN/OUT connector: 50 Ohm
  • IN connector: type 7/16
  • OUT connector: 3" 1/8
  • RF Monitor connector: BNC
  • Three-phase line voltage:208/230/400 VAC (± 15%)
  • Overall consumption: <51kVA - P.F. >0,99  
  • Operating temperature: 0  ÷ 35°C  nominal -5  ÷ 50 °C max
  • Dimensions: 3x19" standard - 120 unit rack
  • Weight: 2250kg.

RFB2005
The new 2Kw output power digital amplifier with preset telemetry offers outstanding performance.

GSM TELEMETRY
Also available the new telemetry system featuring SMS text messages, at very interesting prices.