RFB 505
-
Frequency range: 87.5 ÷ 108 MHz
-
Input power: 12 W nom./20W max.
-
Output power: 500W
-
Output power stability with ALC: ÷ 3%
-
Harmonic attenuation: <70 dBc
-
Input/output impedance: 50 Ohm
-
Input connector: N
-
Output connector: N
-
RF Monitor output connector: BNC
-
Line voltage: 190 ÷ 264 VAC
-
Overall consumption: 1200 VA
-
Maximum current admitted on auxiliary outlets: 1 A @ 230 VAC, no fuse
-
Operating temperature: 0 ÷ +35° C nominal, -10 ÷ +45° C max
-
Dimensions: 42 X 18 X 52 (W - H - L)
-
Weight: 27 Kg
RFB 1005
- Frequency range: 87.5 ÷ 108 MHz
- Input power:12 W nom. / 20 max.
- Output power: 1000 W ÷ 0,5 dB
- Output monitor attenuation: 54 dB, typ.
- Harmonic attenuation: <70 dBc
- Input/output impedance: 50 Ohm
- Input connector: N
- Output connector: 7 / 16"
- RF Monitor output connector: BNC
- Line voltage 190 ÷ 264 VAC 50/60Hz
- Overall consumption: 2000 VA
- Maximum current admitted on auxiliary outlets: 1 A @ 230 VAC, no fuse
- Operating temperature: 0 ÷ 35° C nominal, -10 ÷ 45° C max
- Dimensions:42 X 18 X 52 (W - H - L)
- Weight:30 Kg
RFB 2005
- Frequency range: 87.5 ÷ 108 MHz
- Input power: 20 W nom. / 35 W max.
- Output power: 2000W ÷ 0,5 dB
- Output monitor attenuation: 54 dB, typ.
- Harmonic attenuation: <75 dBc
- Input/output impedance: 50 Ohm
- Input connector: N
- Output connector: 7 / 16"
- RF Monitor output connector: BNC
- Single-phase line voltage: 190 ÷ 264 VAC 50/60 Hz
- Three-phase line voltage (optional) 400 VAC
- Overall consumption: 5200 VA Single-phase - 4000VA Three-phase
- Maximum current admitted on auxiliary outlets: 1 A @ 230 VAC, no fuse
- Operating temperature: 0 ÷ 35° C nominal, -10 ÷ 45° C max
- Dimensions: 42 X 30 X 58 (W - H - L)
- Weight:48 Kg
RFB 5005
- Frequency range: 87,5 ÷ 108 MHz
- Input power, typical/max.: 100 / 130 W
- Output power: 5000 W ± 0,5 dB
- Output power stability with ALC: ±3%
- Harmonic attenuation: <70dB
- IN/OUT impedance: 50 Ohm
- IN connector: type N
- OUT connector: 7/8"
- RF Monitor output connector: BNC
- Three-phase line voltage: 400 VAC (± 15%)
- Overall consumption: <10 kVA - P.F. >0.99
- Maximum current admitted on auxiliary outlets: 3 A @ 230 VAC fused
- Operating temperature: 0 ÷ 35°C nominal, -5 ÷ +50 °C max
- Dimensions: 19" rack
- Weight: 260 kg.
RFB 10005
- Frequency range: 87,5 ÷ 108 MHz
- Input power, tipica/max:250 / 300 W
- Output power: 10000 W ± 0,5 dB
- Output power stability with ALC: ±3%
- Harmonic attenuation: >70dB
- IN/OUT connector: 50 Ohm
- IN connector: type N
- OUT connector: 1" 5/8
- RF Monitor connector: BNC
- Three-phase line voltage: 400 VAC (± 15%)
- Overall consumption: <20kVA - P.F. >0,99
- Maximum current admitted on auxiliary outlets: 6,3 A @ 230 VAC fused
- Operating temperature: 0 ÷ 35°C nominal -5 ÷ 50 °C max
- Dimensions: 19" standard - 40 unit rack
- Weight: 610 kg.
RFB 20005
- Frequency range: 87,5 ÷ 108 MHz
- Input power, typical/max: 1000 W
- Output power: 20000 W ± 0,5 dB
- Output power stability with ALC: ±3%
- Harmonic and spourius emission: -83dBm
- IN/OUT connector: 50 Ohm
- IN connector: type 7/16
- OUT connector: 3" 18
- RF Monitor connector: BNC
- Three-phase line voltage:208/230/ 400 VAC (± 15%)
- Overall consumption: <36kVA - P.F. >0,99
- Maximum current admitted on auxiliary outlets: 6,3A@230VAC fused
- Operating temperature: 0 ÷ 35°C nominal -5 ÷ 50 °C max
- Dimensions: 2x19" standard - 80 unit rack
- Weight: 1500kg.
RFB 30005
- Frequency range: 87,5 ÷ 108 MHz
- Input power, typical/max: 800 / 1000 W
- Output power: 30.000 W ± 0,5 dB
- Output power stability with ALC: ±3%
- Harmonic and spurius emission: -80dBm
- IN/OUT connector: 50 Ohm
- IN connector: type 7/16
- OUT connector: 3" 1/8
- RF Monitor connector: BNC
- Three-phase line voltage:208/230/400 VAC (± 15%)
- Overall consumption: <51kVA - P.F. >0,99
- Operating temperature: 0 ÷ 35°C nominal -5 ÷ 50 °C max
- Dimensions: 3x19" standard - 120 unit rack
- Weight: 2250kg.